Objective

The objective of this project is to address one of the main barriers to implantable islet cell replacement strategies for Type 1 diabetes: the foreign body response (FBR) to implanted devices, which can limit long-term graft survival and function. There is a clear need for strategies to “better understand the underlying mechanisms, improve monitoring approaches, and be able to mitigate and control the FBR.” In direct response to that need, the primary goal of this study is to identify predictive biomarkers of FBR and determine whether those biomarkers are translatable across species, from rats to non-human primates to humans. A persistent challenge in the field is the gap between preclinical performance and clinical outcomes, reflecting a lack of predictive models and an incomplete understanding of human FBR biology. A central objective here is therefore to improve the predictive value of preclinical models by aligning longitudinal, mechanistic readouts across species. This approach directly addresses the RFA’s focus on strengthening “mechanistic understanding of the human immune and stromal response” and developing “human-relevant experimental platforms or analytical approaches” that improve prediction. Importantly, the long-term impact of FBR on directly vascularized implant systems remains insufficiently understood, despite the increasing emphasis on vascularized designs for cell replacement.

To accomplish these objectives, we will use NICHE, a retrievable, directly vascularized subdermal platform designed for cell transplantation and localized immune modulation, now progressing toward clinical trials. Beyond its clinical relevance, NICHE offers a capability that is uncommon in this space: a transcutaneously accessible reservoir that allows minimally invasive, repeated sampling of local interstitial fluid from the peri-/intra-device microenvironment. This enables longitudinal tracking of immune and fibrosis-related cues over time without disturbing the implant site, providing a monitoring approach needed to link early biology to later fibrosis and device performance.

The study is deliberately structured around cross-species comparison. We will first identify soluble biomarker in rats using statistically powered cohorts, with explicit attention to sex as a biological variable. We will then test whether the most informative signatures and mechanisms are conserved in non-human primates, consistent with the RFA’s emphasis on large-animal/NHP models. Finally, we will evaluate translatability in human clinical samples obtained through a Phase I NICHE trial that is independent of this grant and scheduled to run in parallel with the later stages of the project. That alignment is unique and provides a direct opportunity to compare preclinical trajectories with human device-associated responses using the same device architecture and sampling strategy.

In summary, the central objective of this proposal is to deliver predictive, clinically useful biomarkers of FBR and to validate their translatability across rats, NHPs, and humans, supporting improved monitoring and more reliable advancement of beta cell replacement devices toward clinical success.

Background Rationale

Implantable macroencapsulation devices are extensively investigated as a means to transplant insulin-producing cells for individuals with Type 1 diabetes (T1D). These approaches aim to provide durable insulin production using a subdermal, retrievable implant that can be removed if safety concerns arise. A principal barrier to sustained function, however, is the foreign body response (FBR), the host reaction to an implanted material. FBR typically begins with local inflammation and immune cell recruitment and can evolve into fibrotic encapsulation. When fibrosis develops around an implant, it can restrict oxygen and nutrient transport, impair vascular integration, and ultimately compromise the viability and performance of the transplanted cells. Direct vascularization is increasingly incorporated into implant designs to enhance oxygenation and nutrient delivery. While vascularization is expected to improve graft support, the long-term consequences of FBR in directly vascularized implant systems remain insufficiently characterized. Fibrotic remodeling at the device–tissue interface can still occur and may progressively erode the benefits conferred by vascularization. For this reason, improved mechanistic understanding and monitoring of FBR are essential even for advanced vascularized platforms intended for clinical use.

This project is built around NICHE (Neovascularized Implantable Cell Homing and Encapsulation), a retrievable, subdermal cell transplantation platform designed to promote peri-implant vascularization and enable localized immune modulation. NICHE is clinically relevant and it is advancing toward first-in-human evaluation. A Phase I NICHE clinical trial, independent of this grant, is scheduled to run in parallel with the later stages of this proposed research. This synchronization is unique and creates a valuable opportunity to compare preclinical findings directly with human clinical samples, without the need to initiate a separate specimen-generation effort.

NICHE also provides a distinctive technical advantage for studying FBR over time. The platform incorporates a transcutaneously accessible reservoir intended for local drug delivery. Interstitial fluid from the peri- and intra-implant microenvironment can permeate into this reservoir, enabling repeated sampling through a simple transcutaneous needle-based aspiration procedure. This design supports longitudinal measurement of cytokines and other soluble biomarkers from the local interface environment without direct disruption of the transplant site. In contrast, many hydrogel- or scaffold-based transplant approaches lack a dedicated sampling compartment; sampling often requires invasive procedures that can perturb the tissue and introduce confounding inflammation. NICHE therefore enables a more reliable assessment of temporal biomarker trajectories associated with FBR.

The study is structured to support cross-species translation. Rats enable statistically powered studies to define biomarker trajectories and mechanistic drivers of fibrosis while incorporating key biological variables, including sex, given well-recognized sex-dependent differences in immune and fibrotic responses. Non-human primates provide an essential intermediate model with closer physiological and immunological relevance to humans, allowing rigorous evaluation of whether rat-identified signatures are conserved in a human-proximal setting. Although porcine models are often considered attractive for subdermal implant studies, they are not well-suited for the objectives of this proposal because pig-specific immune reagents, validated biomarkers, and standardized assays remain comparatively limited, restricting the depth and reliability of mechanistic and biomarker-driven immune profiling. Together, this cross-species strategy, anchored by parallel clinical sampling, aims to generate a clinically relevant framework for monitoring and predicting FBR in vascularized implant systems, thereby strengthening the pathway toward successful translation of cell replacement therapies for T1D.

Description of Project

Implantable macroencapsulation technologies are extensively investigated to enable transplantation of insulin-producing cells for Type 1 diabetes (T1D), but a major cause of failure remains the foreign body response (FBR), the body’s reaction to an implanted material. FBR often begins with local inflammation and can progress to a dense fibrotic capsule that restricts oxygen and nutrient transport, ultimately impairing or destroying transplanted cells. Despite substantial advances in device engineering, the field still lacks practical, longitudinal methods to monitor FBR over time and to determine which biomarkers and tissue readouts in animal studies reliably predict clinical outcomes in people.

This project addresses that gap using the NICHE (Neovascularized Implantable Cell Homing and Encapsulation) platform, a clinically relevant, retrievable subdermal cell transplantation device designed to promote vascularization and enable localized immune modulation. NICHE is uniquely suited for this investigation because, unlike most scaffold- or hydrogel-based approaches, it enables repeated, minimally invasive sampling of fluid from the transplant microenvironment through a transcutaneously accessible reservoir. In other systems, sampling near the graft may require invasive procedures that can disrupt tissue, compromise the transplant, and confound interpretation of the immune response. With NICHE, local interstitial fluid can be collected at multiple timepoints using a simple needle-based procedure, allowing longitudinal measurement of immune- and fibrosis-related biomarkers without perturbing the graft site.

The study is structured to connect discovery in animals to clinical relevance. First, in rats, we will define early and chronic stages of FBR and identify soluble biomarker patterns that predict later fibrotic encapsulation. Rats enable sufficiently large, statistically powered cohorts to test key variables and establish robust relationships between biomarker trajectories and tissue-level fibrosis. Next, we will evaluate the most informative signatures in cynomolgus macaques, a non-human primate model that more closely reflects human physiology and immune complexity, providing a critical translational bridge between rodents and patients. While porcine models are often cited as relevant for subcutaneous implant studies, they are not suitable for the objectives of this proposal: the limited availability of validated pig-specific immune biomarkers, reagents, and standardized high-dimensional assays would severely restrict mechanistic resolution and materially undermine comprehensive biomarker discovery and cross-platform comparability. In contrast, non-human primates support the full suite of immune and spatial profiling approaches required to execute the proposed cross-species biomarker and mechanistic framework.

A defining strength of this proposal is a rare opportunity for direct comparison to human specimens. A Phase I NICHE clinical trial, funded and executed independently of this grant, is scheduled to run in parallel with the later stages of the project. This parallel effort is expected to generate human explant tissues and longitudinal local samples that can be analyzed within the scope of this proposal without requiring a separate, grant-funded clinical specimen-generation program. Such synchronization between a mechanistic preclinical study and an independent, contemporaneous clinical trial is highly unusual in implant and transplantation research and provides an exceptional opportunity to benchmark cross-species findings using the same device architecture and sampling strategy.

The expected outcome is a practical, clinically relevant framework to monitor FBR over time, identify early warning biomarkers of harmful fibrosis, and accelerate translation of vascularized implant technologies for T1D and other cell-based therapies.

Anticipated Outcome

This project is expected to deliver a practical and clinically relevant framework for understanding, monitoring, and ultimately predicting the foreign body response (FBR) that limits performance of implantable macroencapsulation devices for insulin-producing cell transplantation in Type 1 diabetes (T1D). A central anticipated outcome is the identification of predictive, measurable biomarkers, detectable in local peri-/intra-implant interstitial fluid, that signal the early development of inflammation and fibrotic remodeling before a mature fibrotic capsule compromises graft function. Because FBR can still evolve over time even in directly vascularized implant systems, the study will clarify how immune and stromal processes progress in vascularized designs and which features are most closely linked to later encapsulation and loss of performance.

A second expected outcome is a longitudinal dataset that links soluble biomarker trajectories to quantitative tissue endpoints (immune cell infiltration, collagen deposition, and capsule architecture) and to functional measures of graft performance. These longitudinal measurements are enabled by NICHE’s transcutaneously accessible reservoir, which permits repeated, minimally invasive sampling of local fluid without disrupting the transplant site. This is a key advantage over many other transplant approaches, where sampling near the graft can damage tissue, perturb the microenvironment, and introduce confounding inflammation that complicates interpretation.

The study is also designed to generate results that are informative for translation. In rats, statistically powered cohorts will allow evaluation of critical biological variables, including sex as a biological variable, given well-recognized differences in immune and fibrotic responses between males and females. Findings will then be tested in cynomolgus macaques to determine whether the most informative biomarker and mechanistic signatures are conserved in a model with closer physiological and immunological relevance to humans. This step is expected to improve confidence in which readouts are likely to be clinically meaningful.

A defining anticipated outcome is direct comparison with human clinical specimens. A Phase I NICHE clinical trial, independent of this grant, is scheduled to run in parallel with the later stages of the project, providing access to explant tissues and longitudinal local samples without the need for a separate specimen-generation effort. This synchronization is uncommon in implant research and will strengthen conclusions regarding translatability from rats to non-human primates to humans. Collectively, these outcomes are expected to support biomarker-informed monitoring strategies, guide optimization of NICHE as it advances toward clinical trials and provide broadly applicable insight for other vascularized implant platforms in T1D and related cell-based therapies.

Relevance to T1D

Type 1 diabetes (T1D) is caused by immune-mediated destruction of insulin-producing beta cells. Although insulin therapy is essential, it does not restore physiologic glucose regulation and many individuals continue to face substantial burden from glycemic variability, hypoglycemia risk, and long-term complications. For this reason, transplantation of insulin-producing cells, donor islets or stem cell–derived beta cells, remains a major therapeutic goal, with the potential to provide more durable, biologic glucose control. Implantable macroencapsulation devices placed under the skin are a promising strategy to enable cell replacement in T1D because they can be retrieved if needed and support standardized, scalable cell approaches. However, long-term function is frequently limited by the foreign body response (FBR) to implanted materials. FBR begins with local inflammation and can progress to fibrotic encapsulation that restricts oxygen and nutrient transport and compromises graft survival. This limitation is especially relevant for the next generation of devices that rely on direct cell vascularization to enhance graft support. While vascularized designs are intended to improve oxygenation and function, the long-term impact of FBR in directly vascularized systems is not well defined. For technologies approaching clinical testing, it is therefore fundamental to understand how FBR evolves over time, how it affects vascular integration and mass transport, and whether early local signals can predict later fibrosis and performance.

This proposal is directly aligned with that clinical need because it centers on NICHE (Neovascularized Implantable Cell Homing and Encapsulation), a retrievable, directly vascularized subdermal platform with potential for impact in T1D and a defined path toward first-in-human evaluation. NICHE is designed to address key barriers in cell replacement by promoting vascularization and enabling localized immune modulation, with the goal of reducing or avoiding systemic immunosuppression through targeted delivery of immunomodulatory agents at the implant site. In addition, NICHE offers a unique capability for monitoring: a transcutaneously accessible reservoir that allows repeated, minimally invasive sampling of local interstitial fluid from the peri-/intra-implant microenvironment through a brief needle-based procedure. This enables longitudinal measurement of immune and fibrosis-related biomarkers without disturbing the transplant site or introducing confounding inflammation from direct tissue sampling.

The study is structured to maximize relevance to T1D translation. Rat studies will provide statistically powered investigation of biomarker trajectories while explicitly incorporating sex as a biological variable, given known sex-dependent differences in immune and fibrotic responses. Non-human primate studies will then test conservation of key signatures in a model that more closely reflects human immune and metabolic physiology. Finally, a Phase I NICHE clinical trial, independent of this grant and scheduled to run in parallel with the later stages of the project, will provide access to human clinical samples without requiring a separate specimen-generation effort. By clarifying long-term FBR biology in a directly vascularized, clinically advancing platform and identifying predictive biomarkers, this work is positioned to accelerate safer and more reliable cell replacement for T1D.