Objective

The goal of this project is to create and test a minimally invasive way to measure the body’s own insulin production in people with type 1 diabetes. We will do this by developing a small microneedle skin patch that captures C-peptide, an established marker of insulin made by the pancreas, from the fluid just under the skin. We aim to make the measurement fast, sensitive enough to detect very low levels, and practical for point-of-care or future at-home use.

Specifically, we will (1) optimize the microneedle patch so it can capture C-peptide within five minutes, (2) build a compact cartridge that automates the testing steps and provides results in about fifteen minutes with minimal user handling, and (3) evaluate the system in a human study to confirm that C-peptide patterns measured from skin fluid match medically meaningful changes seen in blood during a standardized meal test.

Background Rationale

C-peptide is the best measure of how much insulin the body is still able to make. In type 1 diabetes, the immune system damages insulin-producing cells, but many people still have some remaining function. Even small amounts of residual insulin production can be clinically meaningful and are especially important for evaluating new therapies designed to preserve or restore β-cell function.

Today, C-peptide is usually measured using clinic-based tests such as a mixed-meal tolerance test. These tests require repeated blood draws through a catheter over several hours, trained personnel, and specialized facilities. Because they are inconvenient and invasive, they are not performed frequently, which means important short-term changes and day-to-day variability in C-peptide are often missed.

A microneedle patch offers a less invasive approach. Microneedles can access interstitial fluid under the skin without pain or bleeding. Interstitial fluid contains many of the same biomarkers as blood, and changes over time often track closely with blood levels. However, in people with type 1 diabetes, C-peptide can be extremely low, especially in long-standing disease, and levels in interstitial fluid can be much lower than in blood. That is why this project combines microneedle capture with an ultrasensitive detection method designed to measure very small amounts of C-peptide.

Creating a compact, user-friendly test format is also essential for translation. Automating the assay steps in a small cartridge can shorten testing time and make frequent measurements feasible in clinic-adjacent settings and, ultimately, at home.

Description of Project

Type 1 diabetes (T1D) happens when the immune system damages the pancreas cells that make insulin. Even after diagnosis, many people with T1D still make small amounts of insulin for some time. Knowing how much insulin the body can still make is important because it relates to better glucose stability and helps researchers evaluate whether new therapies are preserving or restoring these insulin-producing cells.

C-peptide is the best “gold-standard” marker of the body’s own insulin production. Today, measuring C-peptide typically requires a clinic visit and an invasive test such as a mixed-meal tolerance test (MMTT). During an MMTT, a person drinks a standardized meal, and blood is drawn repeatedly through a catheter to see how C-peptide changes over time. These tests are burdensome, require trained staff and equipment, and are not practical for frequent monitoring or at-home use. As a result, important day-to-day and within-day changes in C-peptide are often missed.

This project will develop and test a minimally invasive microneedle patch that can measure C-peptide from interstitial fluid (the fluid just under the skin) instead of blood. Microneedles are tiny and designed to access skin fluid without pain or bleeding. The patch uses high-affinity antibodies to capture C-peptide from the skin within minutes, followed by a highly sensitive fluorescent test to quantify how much C-peptide was captured. Because C-peptide levels in interstitial fluid can be much lower than in blood, especially in people with long-standing T1D, this project uses an ultrasensitive detection method to measure very low concentrations.

We will also create a compact “point-of-care” cartridge that automates the testing steps so results can be obtained quickly with minimal user handling. To make the patch practical for real-world use, we will develop a protective coating that helps preserve antibody function during storage and shipping, even under warm or humid conditions.
Finally, we will evaluate the system in a human study of healthy adults and adults with T1D. We will compare microneedle-quantified C-peptide to standard blood measurements during a mixed-meal test, and we will also use a standard interstitial fluid sampling method (microdialysis) as an additional reference.

If successful, this work will enable convenient, high-frequency C-peptide monitoring that could improve how residual β-cell function is assessed, reduce reliance on burdensome clinic tests, and strengthen clinical trial endpoints for therapies aiming to preserve or restore β-cell function in T1D.

Anticipated Outcome

At the end of this project, we expect to deliver a microneedle-based C-peptide monitoring system that is (1) minimally invasive, (2) highly sensitive, and (3) fast and practical to use. The system is designed to collect C-peptide from the fluid just under the skin within a few minutes and provide a clear numerical result soon after using a small automated cartridge and a portable reader.

We also expect to generate clinical evidence that C-peptide patterns measured from the microneedle patch reflect physiologically meaningful changes seen in blood during a standardized meal test. This includes showing that the patch can detect rises and falls after a meal and that the timing and overall trends are strongly correlated with standard blood measurements. We will also assess safety and comfort to confirm that repeated applications are feasible and well-tolerated.

Together, these outcomes will lay the groundwork for larger studies and future product development aimed at point-of-care and at-home monitoring of residual β-cell function.

Relevance to T1D

For people with type 1 diabetes, preserving or restoring the body’s ability to produce insulin remains a major goal. C-peptide is the key marker used to determine whether the pancreas is still making insulin and to evaluate whether new therapies are working. However, current C-peptide tests are burdensome, invasive, and generally limited to occasional clinic visits, which restricts how well clinicians and researchers can understand real-world changes in β-cell function.

A minimally invasive microneedle-based C-peptide test could make it possible to monitor residual insulin production more frequently and with less disruption. This could improve clinical trials by providing more sensitive endpoints and capturing variability that is missed by occasional blood draws. It could also help researchers better understand patterns of β-cell function across disease duration and potentially support more personalized assessment of therapeutic response.

By making C-peptide monitoring easier, faster, and less invasive, this project addresses an important unmet need in type 1 diabetes research and may accelerate the development and evaluation of therapies aimed at preserving or restoring β-cell function.